The artificial network HV-AN 500 offers a solution for high current and high voltage connections to the EUTs. The AN is used to simulate the impedance of a vehicle harness to determine the behavior of EUT and meet the requirements of ISO 7637-2 and the HV part of CISPR 12 (draft), CISPR 25, ECE No. 10 R05 / 06, ISO 11452-1 and ISO / DTS 7637-4. The optional available HV-AN 500-option-1μF, connected on the AE port of the HV-AN 500, allows testing of the LV part of CISPR 25, ECE No. 10 R06 and ISO 11452-1.
- 5 μH AN/LISN
- High voltage part of CISPR 12 (draft), CISPR 25, ECE No. 10 R05 / R06, ISO 11452-1 and ISO/DTS 7637-4
- ISO 7637-2
- Low voltage part of CISPR 25, ECE No. 10 R06 and ISO 11452-1 with HV-AN 500-option-1μF